<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EETim &#187; Power compensation factor</title>
	<atom:link href="https://eetim.ro/category/products/tablouri-electrice-cat/compensare-factor-de-putere-cat/feed/" rel="self" type="application/rss+xml" />
	<link>https://eetim.ro</link>
	<description>Echipamente de Automatizare</description>
	<lastBuildDate>Thu, 19 Sep 2024 17:22:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.4.2</generator>
		<item>
		<title>Power factor compensation</title>
		<link>https://eetim.ro/en/products/tablouri-electrice-cat/compensare-factor-de-putere-cat/produs-6/</link>
		<comments>https://eetim.ro/en/products/tablouri-electrice-cat/compensare-factor-de-putere-cat/produs-6/#comments</comments>
		<pubDate>Sat, 07 Jul 2012 08:53:57 +0000</pubDate>
		<dc:creator>administrator</dc:creator>
				<category><![CDATA[Power compensation factor]]></category>
		<category><![CDATA[Electric switchboards]]></category>

		<guid isPermaLink="false">http://eetim.ro/?p=266</guid>
		<description><![CDATA[Electrical panels for reactive power compensation Transformers, electric motors, ballast coils, air conditioning systems etc, comsume reactive energy. Reactive energy circulation leads to: increased costs in electricity bill increased equipment costs by increasing the installed power additional losses of active and additional voltage drops in conductors decrease available power in the secondary of the transformer Reducing the above mentioned equipments is &#8230; <a href="https://eetim.ro/en/products/tablouri-electrice-cat/compensare-factor-de-putere-cat/produs-6/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>Electrical panels for reactive power compensation</p>
<p>Transformers, electric motors, ballast coils, air conditioning systems etc, comsume reactive energy. Reactive energy circulation leads to:</p>
<ul>
<li>increased costs in electricity bill</li>
<li>increased equipment costs by increasing the installed power</li>
<li>additional losses of active and additional voltage drops in conductors</li>
<li>decrease available power in the secondary of the transformer</li>
</ul>
<p>Reducing the above mentioned equipments is made via automatic compensation of reactive power, made with the following basic components:</p>
<ul>
<li>compensation capacitors</li>
<li>contactors for connection / disconnection of capacitors</li>
<li>power factor controller</li>
</ul>
<p>The compensation is achieved by calculating the reactive power consumed permanently, based on direct measurement of phase voltage / line voltage and phase using an external current transformer. Depending on the calculated value of power factor regulator control circuit inserting or removing the gear compensation after a predetermined adjustment program.</p>
<p>Main technical characteristics of switchboards for reactive power compensation:</p>
<ul>
<li>Rated power: &#8211; 22.5 &#8230; 100 kVAr in enclosure                                                                                                     &#8211; 300 -100 enclosure kVAr in kVAr in cabinet</li>
<li>Nominal voltage: &#8211; 230 &#8230; 240 V / 50 &#8230; 60 Hz                                                                                                          &#8211; 400 &#8230; 415 V / 50 &#8230; 60 Hz</li>
<li>Number of speed control: &#8211; 1 &#8230; 6 with R6 Varlogic regulator                                                                                                &#8211; 1 &#8230; 12 with R12 Varlogic regulator</li>
<li>Panel size: &#8211; 500x500x250 mm minimum                                                                                                          &#8211; maximum 600x800x2000 mm</li>
<li>Working temperature: 0 &#8230; + 45 grd.C</li>
<li>Protection level: IP30 &#8211; IP55</li>
</ul>
<p>EETim SA implemented equipment for reactive power compensation:</p>
<ul>
<li>VarPlusCan pole capacitor modules / VarPlusBox &#8211; Schneider Electric, or Enerlux</li>
<li>Power factor controllers: Varlogic R6 / R12 Varlogic (Schneider Electric)</li>
<li>Contactors: LC1-DK Series (Schneider Electric)</li>
</ul>
<div class="specificatii-pr"><span class="box-icon"><span data-icon="v" class="icon-b ico-medium "></span></span><h4 class="event-title">Documentation</h4><div class="event-info"></p>
<ul>
<li><a href="http://eetim.ro/wp-content/uploads/2012/07/Condensatori-Schneider-Electric.pdf">Schneider Electric Capacitors</a></li>
<li><a href="http://eetim.ro/wp-content/uploads/2012/07/Condensatori-Enerlux.pdf">Enerlux Capacitors</a></li>
</ul>